(1) A person conducting a business or undertaking must ensure, so far as is reasonably practicable, that while work is being carried out in a confined space, the concentration of any flammable gas, vapour or mist in the atmosphere of the space is less than 5% of its LEL.
(a) In the case of an individual--$6 000.
(b) In the case of a body corporate--$30 000.
Note: Section 12F of the Act provides that strict liability applies to each physical element of each offence under the Act, unless otherwise stated. The reference in section 12F of the Act includes these Regulations.
(2) If it is not reasonably practicable to limit the atmospheric concentration of a flammable gas, vapour or mist in a confined space to less than 5% of its LEL and the atmospheric concentration of the flammable gas, vapour or mist in the space is:
(a) equal to or greater than 5% but less than 10% of its LEL--the person must ensure that any worker is immediately removed from the space unless a suitably calibrated, continuous - monitoring flammable gas detector is used in the space; or
(b) equal to or greater than 10% of its LEL--the person must ensure that any worker is immediately removed from the space.
(a) In the case of an individual--$6 000.
(b) In the case of a body corporate--$30 000.
Note: Section 12F of the Act provides that strict liability
applies to each physical element of each offence under the Act, unless
otherwise stated. The reference in section 12F of the Act includes
these Regulations.