(1) The standards specified for that development are that the development must--(b) not have a floor area of more than--(i) on land in Zone RU1, RU2, RU3, RU4, RU6 or R5--50m 2, or(ii) on land in any other zone--20m 2, and(c) be not higher than 3m above ground level (existing), and(d) be located at a distance from each lot boundary of at least--(i) for development carried out in Zone RU1, RU2, RU3, RU4, RU6 or R5--5m, or(ii) for development carried out in any other zone--900mm, and(e) if it is not on land in Zone RU1, RU2, RU3, RU4 or RU6--be located behind the building line of any road frontage, and(f) not be a shipping container, and(g) be constructed or installed so that roofwater is disposed of without causing a nuisance to adjoining owners, and(h) to the extent it is comprised of metal components--be constructed of low reflective, factory pre-coloured materials if it is located on land in a residential zone, and(i) if it is located on bush fire prone land and is less than 5m from a dwelling--be constructed of non-combustible material, and(j) if it is constructed or installed in a heritage conservation area or a draft heritage conservation area--be located in the rear yard, and(k) if it is located adjacent to another building--be located so that it does not interfere with the entry to, or exit from, or the fire safety measures contained within, that building, and(l) be a Class 10 building and not be habitable, and(m) be located at least 1m from any registered easement, and(n) in relation to a cabana--not be connected to water supply or sewerage services.
(2) There must not be more than 2 developments per lot.