(1) A fence exceeding 2m in height must be set back from a side or rear boundary (including a boundary that is a side or rear street alignment) not less than the distance specified in respect of that boundary in Table 425.
TABLE 425—SIDE AND REAR SETBACKS
Minimum setback from side or rear boundary at that point | |
More than 2·0m but not more than 3·6m |
1m |
More than 3·6m but not more than 6·9m |
1m plus an additional distance calculated at the rate of 300mm for every metre of height over 3·6m |
More than 6·9m |
2m plus an additional distance calculated at the rate of 1m for every metre of height over 6·9m |
(2) This regulation does not apply to a fence that complies with regulation 426.
(3) The report and consent of the relevant council must be obtained to an application for a building permit in relation to a design that does not comply with this regulation.